Products description:
This sensor seriers are open loop current sensors. The primary and secondary coils of the sensors are insulated, which for controlling or measuring DC, AC and pulse currents.
YNC-50A1, YNC-100A1, YNC-200A1 hall current sensor for WTL welder
Work principles:
The magnetic flux generated by the primary current aggregates in the magnetic circuit, which is detected by the hall element in the air gap. The output voltage of the hall element is processed, to output the standard voltage signal at the output end of the sensor. The voltage signal accurtely reflects the changes of the primary current.
Blue and white optional, customized electrical ac current sensor hall for welding machine use
Main electrical parameters:
CE approved industrial grade current sensors in both AC and DC supply with nice price
Rated current(A) |
Measuring range(A) |
Isolation Voltage(KVrms/50HZ/1min) |
Model No. |
50 |
0~±150 |
3.0 |
YNC-50A1 |
100 |
0~±300 |
3.0 |
YNC-100A1 |
200 |
0~±600 |
3.0 |
YNC-200A1 |
300 |
0~±900 |
3.0 |
YNC-300A1 |
400 |
0~±900 |
3.0 |
YNC-400A1 |
500 |
0~±900 |
3.0 |
YNC-500A1 |
600 |
0~±900 |
3.0 |
YNC-600A1 |
Rated measurement output VOUT ±4v
load resistor RM ≥10KΩ
Supply voltage VC ±15V(±5%)
Current consumption IC ≤15mA
Dynamic performance parameters:
Accuracy X ≤1%(+25℃)
Linearity ≤1%(+25℃)
Zero offset voltage VOE ≤ ±30mV (+25℃)
Zero temperature drift TCVOE ≤±1mV/℃ (-40℃~+85℃)
Temperature drift TCVOUT≤0.1/℃
Bandwidth(-3db)BW DC... 50KHZ
Responsonse time Tr≤3us
Follow-up accuracy di/dt>50A/us
General parameters:
Operating temperature TA -40℃~+85℃
Storage temperature TS -40℃~+120℃
Weight: 55g
Product Features:
Easy installation |
No insertion loss |
Strong anti-jamming capability |
Small size, saving space |
Applications:
AC inverters |
DC motor drive static converters |
Communication power supplies |
Uninterruptible power supplies |
Switch power supplies |
Welder power applications |
UPS power suppy |
New energy |
smart transportation |
Chemicals and machinery |
Implementation Standards:
1.The high/low temperature complies with the 9.4.2.1 testing requirements in the EN50178 standard.
2. The moisture and heat conforms to the 9.4.2.2 testing requirements in the EN50178 standard.
3. The vibration conforms to the 9.4.3.2 testing requirements in the EN50178 standard.
4. The EMC conforms to the 9.4.6.1 and 9.4.6.2 testing requirements in the EN50178 standard.
Dimensions:(Unstated tolerance±0.2mm):
For more information , please feel free to contact Ms. Genny Lee, skype: current.sensor , Thanks.